Re: DES Key Decryption Time
Valdis.Kletnieks@vt.edu wrote:
>> In hardware you can unroll the loop and use pipelining giving even 1 cycle
You have n hardware gates making simple operations each with proper latches as needed, all latches use the same clock signal. One data is encoded in L cycles, but a new data set is started in every one cycle.
So yes - processing of one dataset takes L cycles, but processing for example 1G datasets takes 1G +L-1 cycles.
--
Slawek
Received on Wed Apr 9 15:27:23 2003
This archive was generated by hypermail 2.1.8